Description: Description: Introducing our state-of-the-art 12-inch Color High-Resolution TFT Display ICU Patient Monitor, designed to enhance operational efficiency for medical staff. This Multi-parameter Signs Monitor features intuitive screen operation and advanced PVI (Pleth Variability Index) with USB support for easy PDF file export. It seamlessly integrates with nurse call systems via wired or wireless networks. With precise digital SpO2, ECG, NIBP, TEMP, RESP, and PR capabilities, it ensures comprehensive monitoring. Enjoy a unique human voice alarm, and store 720 hours of trend data along with 12 hours of all waveforms. Available in 16 languages including English, French, and Spanish, it’s the perfect solution for modern healthcare environments. Packing List: Package Include: 1×Patient Monitor 1×NIBP Cuff 1×SpO2 Probe 1×5 lead EKG?Cable 1×Temperature Probe 1×NIBP extension cable 5×Electrode 1×User Manual ECG Lead mode : 5 Leads, I, II, III, AVR, AVL, AVF, V Gain : 0.25, ´0.5, ´1, ´2 Heart rate : Adult : 15 ~ 300 bpm Neonatal/Pediatric : 15 ~ 350 bpm Accuracy : 1% Resolution : 1 bpm Sensitivity : > 200 μV P-P Differential Input Impedance : > 5 M ohm Electrode offset potential : 300mV Leakage Current : < 10 μA PACE pulse detect Range : ±2 ~ ±700mV Width : 0.1 ~ 2ms : 10 ~ 100µs PACE pulse rejection Range : ±2 ~ ±700mV Width : 0.1 ~ 2ms : 10 ~ 100µs ST measurement Range ; -2.0 ~ +2.0 mV Accuracy : -0.8mV ~ +0.8mV: ±0.02mV or ±10%, which is greater Respiration Method : Impedance between RA-LL or RA-LA Differential Input Impedance : >2.5 M ohm Respiration Impedance Range : 0.3~3Ω Base Impedance Range : 200Ω-2000Ω Bandwidth : 0.3 ~ 2 Hz Gain : ×0.25 , ×0.500 , ×1 , ×2 , ×4 Respiration Rate Measurement Range Adult : 0 ~ 120 BrPM Neonatal / Pediatric : 0 ~ 150 BrPM Resolution : 1 BrPM Accuracy 0 ~ 6 BrPM: unspecified 7 ~ 150 BrPM: ±2 BrPM or ±2%, the greater Inspiriting current : < 300 µA RMS max Apnea Alarm : 10 ~ 40 s Temperature Channel : 1 Measure and Alarm Range : 0 ~ 50 °C Resolution : 0.1°C Accuracy : ± 0.2℃ NIBP Pulse Rate Range : 40 ~ 240 bpm Measure and Alarm Range Adult Mode SYS : 40 ~ 280 mmHg DIA : 10 ~ 220 mmHg MEAN : 20 ~ 240 mmHg Pediatric Mode SYS : 40 ~ 220 mmHg DIA : 0 ~ 160 mmHg MEAN : 20 ~ 170 mmHg Neonatal Mode SYS : 35 ~ 135 mmHg DIA : 10 ~ 100 mmHg MEAN : 20 ~ 110 mmHg Static pressure accuracy : 3mmHg Resolution : 1mmHg Accuracy Maximum Mean error : 5mmHg Maximum Standard deviation : 8mmHg Over pressure Adult : 300 mmHg Pediatric : 240 mmHg Neonatal : 150 mmHg SpO2 Measurement Range : 0 ~ 100 % Resolution : 1 % Accuracy 2 % for 70% ~ 0% ~ 69% unspecified Pulse Rate Measure and Alarm Range : 20~250bpm Resolution : 1bpm Accuracy : 3bpm FDA Disclaimer: Statement:The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.(Seller name:May City:Beijing State:Beijing Country:China Phone:+86 18108119506) This item has been cleaned and treated according to the manufacturer's instructions. The Fingertip Pulse Oximeter is certified with the US FDA 510K No. K070371, the CE & TUV of Eureope and it is on the Australian Register of Therapeutic Goods (ARTG) with the code 136606. The Powered Surgical Instrument / Speed 808 System is certified with the US FDA 510(k) Number:K132989 The Powered Surgical Instrument / Hair Remove Device is certified with the US FDA 510(k) Number:K180353 The Powered Surgical Instrument / Hair Remove System is certified with the US FDA 510(k) Number:K141973 massager, vacuum, light induced heating / Slimming Treatment Device is certified with the US FDA 510(k) Number:K161892
Price: 1029.06 USD
Location: Chino, California
End Time: 2025-01-23T17:01:08.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Brand: Unbranded
MPN: Does Not Apply