Description: Ultrameter II Conductivity, Resistivity, TDS, pH, ORP/Free Chlorine, Temperature Meter Ultrameter II™ Models4PII Conductivity, Resistivity, TDS, Temperature Meter6PFCE Conductivity, Resistivity, TDS, pH, ORP/Free Chlorine, Temperature MeterORP mV and Free Chlorine-+Autoranging++Adjustable Temp. Compensation++Adjustable Cond/TDS ratio++Memory (100 readings)++Date & Time Stamp++pH Calibration Prompts-+Low battery indicator++Auto-off++ FeaturesORP-based FCE free chlorine measurement, displayed as ppm concentration (only for 6PFCE model)Superior resolution 4 digit LCD displays full 9999 µS/ppmCond/TDS accuracy of ±1% of reading in a handheld instrument ±0.1% at calibration pointAll electrodes are internal for maximum protectionImproved 4 electrode sensor technologyWaterproof to 1 meter/3 feetAutoranging conductivity/TDS/resistivityPrompts for easy pH calibration (only for 6PFCE model)Factory calibrations stored in microprocessor3 conductivity/TDS solution conversions preprogrammed into microprocessorUser mode feature allows: Programming your own cond/TDS conversion factor Programming your own temperature compensation factor Disabling temperature compensationReal Time Clock with Time and DateData Logging with TIME and DATE in memoryMemory stores 100 readingsUser adjustable timeout "Auto oFF"Bluetooth® wireless download capability with optional bluDock™ (only for 4PII-BD or 6PIIFCE-BD model) We are proud of the trust handheld water quality instruments and monitor/controllers have earned in the past. Our product line has evolved to a new level of outstanding performance and value in analytical instruments: the Ultrameter II series. While priced like affordable single-parameter instruments, the Ultrameter II does the job of up to seven instruments. Accuracy You Can Trust Both Ultrameter II models deliver performance of ±1% of reading (not merely full scale). This high level of accuracy has been achieved through advanced four-electrode conductivity cell technology, a unique pH/ORP sensor and powerful microprocessor-based circuitry. With displayed values of up to 9999, the full four-digit LCD ensures resolution levels never before possible in such affordable instruments. Factory calibrated with NIST traceable solutions, each Ultrameter II may be supplied with both certification of traceability and NIST traceable solutions for definitive calibration. Innovative Engineering The Ultrameter II is a prime example of how high-tech engineering can greatly simplify and streamline a task. Whether in the lab, industrial plant, or in a remote field location, merely:Fill the cell cupPush a parameter keyTake the reading Temperature compensation and range selection are both rapid and automatic. The Ultrameter II is a true one-hand operation instrument. Easy to Calibrate All calibrations are quickly accomplished by pressing the Up or Down keys to agree with NIST traceable Standard Solution. When calibration is necessary, display prompts simplify pH calibration and make sure the correct buffer is being used. Plus, all parameters (excluding factory-set temperature) have an internal electronic setting that can be used for field calibration and as a check on pH/ORP sensor life. NEW! FCE TM FAC Readings The Myron L® Company FCE function reports FAC quickly and accurately by measuring ORP, the chemical characteristic of chlorine that directly reflects its effectivity, cross referenced with pH. Both DPD kits and colorimeters may tell the user the FAC value of the sample in the test tube, but since the chemistry of that sample is quite different from the source water being analyzed, the results are imprecisely related to actual disinfection power. The Myron L® Company FCE function measures the real, unaltered chemistry of source water, including moment-to-moment changes in that chemistry. High Performance at a Low Cost Beyond their affordable purchase price, Ultra-Fast, Ultra-Easy, Ultra- Powerful Ultrameter IIs save both time and money. Measure for measure, Ultrameter IIs give you a better return on your investment than any other handheld instrument. To see for yourself, contact your distributor or the Myron L® Company today. ULTRAMETER™ II Features & Benefits:3 solution standards for greatest accuracy in diverse applications.Fully automatic temperature compensation.User adjustable temperature compensation (up to 9.99%/°C) which also allows TC to be disabled for applications requiring non-compensated readings.User adjustable conductivity/TDS conversion ratio for greater accuracy when measuring solutions not contained in the microprocessor.Auto-shutoff maximizes the life of the single 9V battery to more than 100 hours/5000 tests.Non-volatile microprocessor provides data back-up, even when the battery is changed. This assures all calibrations and memory data will be retained.Extended life pH/ORP sensor is user replaceable in the field. Display 4 Digit Liquid Crystal Display Weight 352 g/12.4 oz. Case/conductivity cell material VALOX* Cell capacities pH/ORP: 1,2 ml/0.04 oz. Cond/TDS/Res: 5 ml/0.2 oz. Power 9V alkaline battery Battery life >100 hours (5000 readings) Operating/storage temperature 0 – 55°C/32 – 132°F Protection ratings IP67/NEMA 6 Waterproof to 1 meter/3 feet * ® Sabic Innovative Plastics Parameters Conductivity TDS Resistivity pH ORP Free Chlorine Temperature Ranges 0–9999µS/cm 10–200mS/cm in 5 autoranges 0–9999ppm 10–200ppt in 5 autoranges 10KΩ–30MΩ 0–14pH ±999mV 0.00–9.99ppm 350≤ORPmV<725 and 0.0≤pH<9.9 725≤ORPmV<825 and 0.0≤pH<8.9 0–71°C 32–160°F Resolution 0.01(<100µS) 0.1(<1000µS) 1.0(<10mS) 0.01(<100mS) 0.1(<200mS) 0.01(<100ppm) 0.1(<1000ppm) 1.0(<10ppt) 0.01(<100ppt) 0.1(<200ppt) 0.01(<100KΩ) 0.1(<1000KΩ) 0.1(>1MΩ) ±0.01pH ±1mV 0.01ppm 0.1°C/F Accuracy ±1% of reading ±1% of reading ±1% of reading ±0.01 pH* ±1 mV <1.00ppm ±0.3ppm* ≥1.00ppm ±0.2ppm ±0.1°C - Auto Temperature Compensation 0–71°C 32–160°F 0–71°C 32–160°F 0–71°C 32–160°F 0–71°C 32–160°F - 0–71°C 32–160°F - Adjustable Temperature Compensation to 25ºC 0–9.99%/°C 0–9.99%/°C 0–9.99%/°C - - - - Conductivity/TDS Ratios Preprogrammed KCl, 442™**, NaCl KCI, 442™**, NaCl - - - - - Adjustable Conductivity/TDS Ratio Factor 0.20–7.99 0.20–7.99 - - - - - *± .2 pH in presence of RF fields ≥ 3V/m and >300MHz **442 Natural Water Standard™ Myron L® Company
Price: 1345 USD
Location: Casper, Wyoming
End Time: 2024-12-13T10:16:19.000Z
Shipping Cost: N/A USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 14 Days
Refund will be given as: Money Back
Brand: Myron L
Unit Type: Unit
pH Range: 0–14pH
Conductivity Range: 10–200mS/cm
TDS Range: 10–200ppt
Product: Conductivity Meter
MPN: 6PIIFCE
Unit Quantity: 1