Description: BRAND NEW 35 CFM SCHULZ NON CYCLING REFRIGERATED COMPRESSED AIR DRYER FOR AIR COMPRESSORS. WHAT IS A NON CYCLING REFRIGERATED AIR DRYER AND WHY DO I NEED ONE ? COMPRESSED AIR CONTAINS NATURALLY OCCURRING MOISTURE, WHICH CAN NEGATIVELY AFFECT COMPRESSED AIR APPLICATIONS THAT REQUIRE MOISTURE FREE AIR. DRYERS ARE A COMMON SOLUTION FOR REMOVING SUCH MOISTURE. ONE OF THE MOST POPULAR OPTIONS ARE REFRIGERATED AIR DRYERS, DUE TO ITS ABILITY TO REACH AN ACCEPTABLE DEW POINT IN. NON-CYCLING REFRIGERATED DRYERS, THE REFRIGERANT ACTUALLY CIRCULATES CONTINUOUSLY THROUGHOUT THE SYSTEM. BECAUSE BOTH THE FLOW OF COMPRESSED AIR AND AMBIENT TEMPERATURES VARY, A HOT GAS BYPASS VALVE IS USED TO REGULATE THE TEMPERATURE OF THE REFRIGERANT WHILE PREVENTING FREEZING WITHIN THE SYSTEM.PLEASE NOTE: IT IS VITAL THAT LIQUID WATER AND OIL ARE REMOVED FROM YOUR COMPRESSED AIR LINES BEFORE ENTERING ANY REFRIGERATED AIR DRYER. LIQUID WATER AND/OR OIL FROM YOUR COMPRESSOR CAN DAMAGE THE INTERIOR COMPONENTS OF THE DRYER RESULTING IN DRYER NON-PERFORMANCE OR FAILURE. AIR TREATMENT SYSTEMS BEFORE THE DRYER ARE NECESSARY: IF YOU CURRENTLY HAVE SOME SORT OF WATER SEPARATOR OR IN-LINE FILTRATION SYSTEM INSTALLED ON YOUR COMPRESSED AIR SYSTEM, PLEASE MAKE SURE IT IS INSTALLED BEFORE THIS REFRIGERATED AIR DRYER. IF YOU DO NOT HAVE COMPRESSED AIR LINE FILTRATION INSTALLED, HERE IS OUR EBAY LISTING FOR THIS 35 CFM DRYER UNIT WITH 2 STAGE WATER SEPARATOR + OIL REMOVING COALESCING FILTER. ( 173953183453 ). COPY & PASTE ITEM CODE TO YOUR EBAY SEARCH BAR. HERE IS OUR LISTING FOR THIS 35 CFM DRYER UNIT THAT COMES EQUIPPED WITH 2 STAGE AIR PRESSURE REGULATOR WATER SEPARATOR COMBO + COALESCING OIL REMOVING FILTER ( 192984706255 ). COPY AND PASTE ITEM CODE TO YOUR EBAY SEARCH BAR. WATER SEPARATION AND MOISTURE REMOVAL INFO: THE MOST EFFECTIVE WAY TO SEPARATE MOISTURE WATER FROM YOUR COMPRESSED AIR IN YOUR COMPRESSED AIR LINES, STARTS WITH THE COMPRESSED AIR LINES THEMSELVES. WHEN YOU ARE SETTING UP OR INSTALLING YOUR PIPING, YOU ALWAYS WANT TO FORCE YOUR COMPRESSED AIR TO CLIMB VERTICALLY, WHILE POOLING LIQUID WATER IS DRIVEN DOWNWARDS BY GRAVITY. USUALLY INTO SOME SORT OF DRAIN OR BALL VALVE THAT IS RELEASED PERIODICALLY. BY DOING THIS, YOU NOT ONLY PROTECT THE REFRIGERATED AIR DRYER AND YOUR PNEUMATIC TOOLS AND SPRAYERS. IF YOU VISIT GOOGLE IMAGES AND SEARCH, "PROPER COMPRESSED AIR LINE INSTALLATION", YOU WILL SEE A WIDE VARIETY OF DIFFERENT INSTALLATION TYPES THAT YOU CAN EMULATE ON YOUR OWN SET UP. YOU CAN ALSO VIEW OUR ATTACHED PICS FOR OUR RECOMMENDED COMPRESSED AIR LINE SET UP WITH FILTERS AND BY PASS. DRYER SIZING: WHEN SIZING A DRYER, IT’S IMPORTANT TO UNDERSTAND HOW TEMPERATURE AND PRESSURE AFFECT WATER CONTENT IN AIR. THE WATER VAPOR CONTENT OF AIR VARIES DIRECTLY WITH TEMPERATURE. IF TEMPERATURE INCREASES, THE AIR’S ABILITY TO HOLD WATER INCREASES. AS A RULE OF THUMB, EVERY 20° F RISE IN INLET AIR TEMPERATURE MAY DOUBLE THE WATER LOAD ON A DRYER. PRESSURE IS THE OPPOSITE. THE WATER VAPOR CONTENT OF AIR VARIES INVERSELY WITH PRESSURE—IF PRESSURE INCREASES, IT SQUEEZES MOISTURE OUT. BECAUSE OF THESE TWO RELATIONSHIPS, COMPRESSED AIR DRYERS HAVE CORRECTION FACTORS (PLEASE SEE OUR ATTACHED PICS FOR THE SCHULZ CORRECTION FACTORS) TO HELP DETERMINE HOW MUCH AIR A DRYER CAN ACTUALLY HANDLE FOR SPECIFIC AMBIENT CONDITIONS. IN SELECTING WHICH CORRECTION FACTORS TO USE, MAKE SURE YOU GO WITH THE WORST CASE SCENARIO. THIS IS USUALLY DURING THE HOTTER, MORE HUMID SUMMER MONTHS. YOU CAN ALSO FIND A VAST AMOUNT OF INFORMATION REGARDING REFRIGERATED AIR DRYER CALCULATORS ONLINE. ADS-35 NON-CYCLING REFRIGERATED AIR DRYER INFORMATIONEACH UNIT COMES COMPLETE WITH VERY DESCRIPTIVE USERS / OPERATION MANUAL. ITS RECOMMENDED THE USERS MANUAL STAYS IN THE PRESENCE OF THE OPERATOR. 220 PSI MAX INPUT PRESSURE TO THE INLET SIDE OF THE DRYER. THIS 35 CFM DRYER HAS A 1/2" FEMALE NPT INLET AND OUTLET. THE INLET AND OUTLET 1/2" FEMALE NPT CONNECTIONS ON THE DRYER ARE MACHINED ALUMINUM. WE PROVIDE YOU WITH HIGH QUALITY BRASS MACHINED HEX BUSHINGS OR UNIONS FOR YOU TO USE ON THE INLET AND OUTLET PORTION OF THE REFRIGERATED AIR DRYER. ITS VERY IMPORTANT THAT YOU DO NOT USE COARSE BLACK IRON PIPE OR GALVANIZED FITTINGS ON THE ALUMINUM INLET/OUTLET PORTION OF THE DRYER. THE COARSE THREADS CAN DAMAGE THE ALUMINUM FITTINGS WHICH COULD LEAD TO A LEAK IN THE PIPING. PLEASE REVIEW THE REQUIRED INSTALLATION GUIDELINES BELOWTECHNICAL INFO:SINGLE PHASECFM: 35 CFM AT 100 PSIMAX INLET PRESSURE: 220 PSI DRYER DEW POINT: 41 DEGREES FAHRENHEIT AT 100 PSI AMBIENT TEMPERATURE: 113 DEGREES FAHRENHEIT MAX 34 DEGREES FAHRENHEIT MINIMUMCONNECTION: 1/2" FEMALE NPT INLET AND OUTLET. ALUMINUM FITTINGS, WE PROVIDE YOU WITH HIGH QUALITY MACHINED BRASS FITTINGS TO USE ON THE INLET AND OUTLET CONNECTION. DEW POINT: 41 DEGREE FAHRENHEIT, 5 DEGREE CELSIUS. PLEASE VIEW ATTACHED CORRECTION FACTORS IN OUR ATTACHED PICS. REFRIGERANT FLUID TYPE: R134aVOLTAGE: 115VWIRE SIZE REQUIRED: 10 GAUGEFREQUENCY: 60hzDIMENSIONS IN INCHES: ( HEIGHT 18.75" ) ( WIDTH 15" ) (LENGTH/DEPTH 20.25")APPROX WEIGHT: 62 LBSSINCE COMPRESSED AIR PIPING INSTALLATION SETS UPS VARY IN LENGTH AND SIZE, WE DO NOT PROVIDE ANY OF THE COMPRESSED AIR TUBING YOU WILL NEED IN ORDER TO PLUMB THIS SYSTEM TOGETHER. PLEASE VISIT OUR STORE FOR A VARIETY OF COMPRESSED AIR TUBING OPTIONS. NEVER USE PVC FOR YOUR COMPRESSED AIR LINE INSTALLATIONS. IF PVC RUPTURES, IT CAN SEND DANGEROUS SHARDS AT TREMENDOUS VELOCITIES THROUGHOUT YOUR WORK SPACE CAUSING SERIOUS INJURY. INSTALLATION REQUIREMENTS FOR ADS SERIES REFRIGERATED AIR DRYERS: LOCATION: THE PRODUCT MUST BE INSTALLED IN AN ENGINE ROOM ACCORDING TO NR13 OF MTB, IN A ROOFED AREA THAT IS WELL VENTILATED, FREE FROM DUST, TOXIC GASES, HUMIDITY OR POLLUTION OF ANY KIND. IN ORDER TO REDUCE THE EXCESS OF NOISE, A SOUNDPROOFING PROJECT MUST BE TAKEN INTO CONSIDERATION. FAILURE TO INSTALL DRYER IN THE PROPER AMBIENT CONDITIONS WILL AFFECT THE DRYER’S ABILITY TO CONDENSE REFRIGERANT GAS. THIS CAN CAUSE HIGHER LOADS ON THE COMPRESSOR, LOSS OF DRYER EFFICIENCY AND PERFORMANCE, OVERHEATED CONDENSER FAN MOTORS, ELECTRICAL COMPONENT FAILURE AND DRYER FAILURE DUE TO THE FOLLOWING: COMPRESSOR LOSS, FAN MOTOR FAILURE AND ELECTRICAL COMPONENT FAILURE. FAILURES OF THIS TYPE WILL AFFECT WARRANTY CONSIDERATIONS. IF THE ROOM TEMPERATURE IS OVER THAT, IT IS NECESSARY TO USE THE FLOW CORRECTION TABLE. THIS APPLIES FACTORS WHICH HELP TO FIND OUT THE CORRECTED DISCHARGE THE DRYER IS ABLE TO PROCESS. THE USE OF EXHAUST FANS IS ALSO RECOMMENDED, COOLING DUCTS, OR OTHER MEANS TO PROVIDE A DECREASE IN TEMPERATURE. IF THE ROOM TEMPERATURE IS NEAR OR LESS THAN 5°C, THE SRS - AIR DRYER IS NOT RECOMMENDED, AS HEATING IS REQUIRED FOR THE MACHINE ROOM AND THE ENTIRE COMPRESSED AIR PIPELINE FOR TEMPERATURES AROUND OR OVER 10°C. THE PRESENCE OF CONTAMINATION AGENTS (DUST, FIBERS, ETC.) SUSPENDED IN THE AIR CAN CAUSE PREMATURE OBSTRUCTION OF THE CONDENSER PLACEMENT: KEEP DRYER AWAY FROM ANY OBSTACLE TO AVOID HARMING THE OPERATION AND AT THE SAME TIME FACILITATING PREVENTIVE MAINTENANCE OF THE ADS - AIR DRYER. DRYERS MODELS ADS 10 – 150 CAN BE WALL-MOUNTED. DIMENSIONS ON DIMENSIONAL DRAWINGS ARE SHOWN IN USERS MANUAL. THE HANGING MOUNTING INEVITABLY CAUSES THE OBSTRUCTION OF THE VENTILATION GRID POSITIONED ON THE PANEL FACING THE WALL FIXING. THIS OBSTRUCTION, IN ANY CASE, DOES NOT PREJUDGE THE EFFICIENCY OF THE VENTILATION INSIDE THE DRYER WHICH IS GUARANTEED BY OTHER GRIDS ON THE OTHER PANELS.FOUNDATION: THE PRODUCT MUST BE INSTALLED ON A CONCRETE BASE CAPABLE OF SUPPORTING ITS WEIGHT AND THE FORCES RESULTING FROM ITS OPERATION. INSTALL THE ADS - AIR DRYER BY REMOVING THE BASE USED FOR SHIPPING.COMPRESSED AIR QUALITY: THE INSTALLATION OF A COALESCENT FILTER OF 1Μ (MICRON) IS INDISPENSABLE IN THE ADS - AIR DRYER INLET FOR THE PURPOSE OF AVOIDING THE ENTRANCE OF OIL AND SOLID PARTICLES WHICH MAY OBSTRUCT OR HARM THE THERMAL EXCHANGE IN THE HEAT EXCHANGER. IF THE AIR PROCESSED BY THE DRYER IS SUPPLIED BY AN ALTERNATING PISTON COMPRESSOR A TOTAL PIPELINE COURSE OF AT LEAST 26 FEET IS RECOMMENDED BETWEEN THE RESERVOIR AND THE DRYER (OR A COALESCENT PRE-FILTER). THIS LENGTH OF PIPELINE HELPS A GREAT DEAL IN COOLING THE COMPRESSED AIR BEFORE GOING INTO THE DRYER. IT DEPENDS ON THE QUALITY OF THE COMPRESSED AIR TO EVALUATE THE NEED OF INSTALLING ONE OR MORE FILTERS. THE PURPOSE IS TO AVOID THE ACCUMULATION OF PARTICLES IN THE LINE.
Price: 10506 USD
Location: Kennesaw, Georgia
End Time: 2024-10-11T13:09:57.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 60 Days
Refund will be given as: Money Back
Return policy details:
Country/Region of Manufacture: Italy
MPN: ADS-35
Compressed Air Dryer Type: Refrigerated Dryer
Airflow Volume: 35 CFM @ 100 PSI
Maximum Compressor Horsepower: 10 HP COMPRESSOR MAX
Maximum Pressure: 220 PSI MAX INPUT
Brand: SCHULZ
California Prop 65 Warning: This product contains or may contain chemicals including lead known in the state of California to cause cancer, birth defects, or other reproductive harm. We suggest washing hands after handling. California law requires this warning be given to all customers in the state of California.
REPLACEMENT FOR: RNP35 D72IN 4NMJ2 Crn35a1 DEIT0035