Description: Thermo Scientific/KeyTek ECAT Surge Simulator/Tester E103/EHV2/E514/E505 Comes with what you see in the pictures. If you don't see it, you probably won't get it. Specifications are from KeyTek and may vary slightly due to upgrades, options, or revisions this unit may or may not have. This unit ships fully tested and guaranteed to work for 30-days, parts and labor, excluding freight. There is no software included. Components included: ECAT Control Center - E-Class Series 100 for ESD/EFT/SURGE/PQF EHV2 2kV High Voltage Supply E000 ECAT Module - Blank E514 Surge Network E505 Surge Network ECAT Model 103 Series Control Center Specifications: Description: Computer-driven control center and power units require dfor the oepration of any Thermo Scientific ECAT test system Virtual Front Panel Control: 8 x 40 character keyboard entry and LCD display - allows operator to see vital test parameters without list scrolling FiberCom Fiber-Optic Interface and Control System: Uses ECAT software (not included) for full computer control of ECAT test equipment (user-supplied PC running Windows, 8 MB, one serial port) Module Bay: For one full-width plug-in module or two-half-width modules. Up to five additional bays (for a total of six) and/or S-ECAT for floor-standing system (required for mroe than three docking bays) Surge V and I Monitor Ports: For waveform monitoring with an external (user-supplied) oscilloscope at 1 kV/V and 200A/V; V & I signals supplied from optional AC coupler/decoupler (not included) or ECAT modules/options Input Voltage: 100-240 VAC, 50/60 Hz Typical Input Current: 3.5 A @ 100 V; 1.5 @ 240 V Operating Temperature: +15°C to +35°C Operating Humidity: 10% to 75% non-condensing. ECAT Model E514 Surge Simulator Specifications: Description: Surge simulator for 10/1000 µs current waves Open-Circuit Voltage: Open-circuit voltage waveforms vary according to the peak short-circuit current level selected: Peak I: Open-Circuit V: 15 A 10/1000 µs, 50-1650 V ±10% 60 A 1 kV/µs linear ramp, 50-1650 V 100 A 10/1000 µs, 50-1000 V 250 A 1 kV/µs linear ramp, 50-1650 V ±10% Short-Circuit Current: 10/1000 µs; software selectable at 15 A, 60 A, 100 A, and 250 A, ±10% Rise Time Tolerance: ±30% Duration Tolerance: ±20% Surge Repetition Rate: 15 A, 60 A - 1 shot/21 seconds; 100 A, 250 A - 1 shot/59 seconds Minimum System Requirements: E100 series control center. ECAT E505 Surge Simulator Specifications: Description: Simulator for FCC Part 68 Telecom Waves Waveforms: <10/>160 µs, 50-1650 V ±10%; peak short-circuit current is 200 A, -0% +10% when the open-circuit voltage is set to 1500 V. <10/>560 µs, 50-880 V ±10%; peak short-circuit current is 100 A, -0% +10% when the open-circuit voltage is set to 800 V <10/>560 µs, 50-880 V ±10%; peak short-circuit current is 200 A, -0% +10% when the open-circuit voltage is set to 800 V <2/>10 µs, 100-2750 V ±10%; peak short-circuit current is 1000 A, -0% +10% when the open-circuit voltage is set to 2500 V Surge Repetition Rate: 1 shot/18 seconds for all waves except <2/>10 µs and <10/>560 µs 200 A, which are 1 shot/24 seconds. Line Sync Accuracy: ±15° with optional coupler/decoupler (not included) Minimum System Requirements: E100 series control center. $100.00 minimum for packaging, handling, and order processing. Shipping to be determined by destination. Prior to shipment I will need to know the following information (filled out on a form that I will send you) for International Customers or Packages/Freight being Forwarded internationally. International customers may also be subject to a freight forwarder form if applicable.: (1) Are you the end-user of this item? (2) If you are not the ultimate end-user of the item, please state the ultimate end user's name. (3) What is the ultimate country destination? 03/04/19
Price: 32499.99 USD
Location: Phoenix, Arizona
End Time: 2023-11-04T21:17:55.000Z
Shipping Cost: N/A USD
Product Images
Item Specifics
All returns accepted: ReturnsNotAccepted
Model: ECAT
MPN: ECAT
Brand: KeyTek